<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>sealant Archives &#183; PHPD Online</title>
	<atom:link href="https://phpdonline.co.uk/tag/sealant/feed/" rel="self" type="application/rss+xml" />
	<link>https://phpdonline.co.uk/tag/sealant/</link>
	<description>the latest news and business info for the housebuilding industry</description>
	<lastBuildDate>Mon, 26 Feb 2024 12:48:19 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	
	<item>
		<title>Sealing for safety</title>
		<link>https://phpdonline.co.uk/features/sealing-for-safety/</link>
		
		<dc:creator><![CDATA[Lily Smith]]></dc:creator>
		<pubDate>Fri, 08 Mar 2024 11:00:11 +0000</pubDate>
				<category><![CDATA[Features]]></category>
		<category><![CDATA[Part L of the Building Regulations]]></category>
		<category><![CDATA[pipes and flues are sealed]]></category>
		<category><![CDATA[sealant]]></category>
		<category><![CDATA[Talon]]></category>
		<guid isPermaLink="false">https://phpdonline.co.uk/?p=26098</guid>

					<description><![CDATA[<p><img width="300" height="175" src="https://phpdonline.co.uk/wp-content/uploads/2024/02/sealing-for-safety-300x175.jpg" class="attachment-medium size-medium wp-post-image" alt="The revision of Part L of the Building Regulations demands that holes around pipes and flues are sealed which may mean working at height..." decoding="async" fetchpriority="high" srcset="https://phpdonline.co.uk/wp-content/uploads/2024/02/sealing-for-safety-300x175.jpg 300w, https://phpdonline.co.uk/wp-content/uploads/2024/02/sealing-for-safety-1024x597.jpg 1024w, https://phpdonline.co.uk/wp-content/uploads/2024/02/sealing-for-safety-768x448.jpg 768w, https://phpdonline.co.uk/wp-content/uploads/2024/02/sealing-for-safety.jpg 1200w" sizes="(max-width: 300px) 100vw, 300px" /></p>
<p>The revision of Part L of the Building Regulations demands that holes around pipes and flues are sealed. And sealing around flues where they exit a building may mean working at height. Dean Heathfield, commercial director at Talon, explains the issue. As part of the move to greater thermal efficiency the latest edition to the ...</p>
<p>The post <a href="https://phpdonline.co.uk/features/sealing-for-safety/">Sealing for safety</a> appeared first on <a href="https://phpdonline.co.uk">PHPD Online</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><img width="300" height="175" src="https://phpdonline.co.uk/wp-content/uploads/2024/02/sealing-for-safety-300x175.jpg" class="attachment-medium size-medium wp-post-image" alt="The revision of Part L of the Building Regulations demands that holes around pipes and flues are sealed which may mean working at height..." decoding="async" loading="lazy" srcset="https://phpdonline.co.uk/wp-content/uploads/2024/02/sealing-for-safety-300x175.jpg 300w, https://phpdonline.co.uk/wp-content/uploads/2024/02/sealing-for-safety-1024x597.jpg 1024w, https://phpdonline.co.uk/wp-content/uploads/2024/02/sealing-for-safety-768x448.jpg 768w, https://phpdonline.co.uk/wp-content/uploads/2024/02/sealing-for-safety.jpg 1200w" sizes="auto, (max-width: 300px) 100vw, 300px" /></p><div id="phpdo-2411375500" class="phpdo-before-content phpdo-entity-placement"><!-- /111384791/phpd-sponsored-leaderboard -->
    <div id='div-gpt-ad-1556702653500-0'>
    <script>
    googletag.cmd.push(function() { googletag.display('div-gpt-ad-1556702653500-0'); });
    </script>
    </div></div><p><strong><span style="color: #0084dc;">The revision of Part L of the Building Regulations demands that holes around pipes and flues are sealed. And sealing around flues where they exit a building may mean working at height. Dean Heathfield, commercial director at Talon, explains the issue.</span></strong></p>
<p>As part of the move to greater thermal efficiency the latest edition to the Building Regulations has tightened up Part L, requiring that holes around pipework must be sealed in order to maintain the energy efficiency of the building, prevent water ingress and stop insects and pests from entering the premises.</p><div id="phpdo-189549212" class="phpdo-content phpdo-entity-placement"><!-- /111384791/phpd-inline-mpu-1 -->
<div id='div-gpt-ad-1549639897910-0' style="border: 0pt none;width: 300px; margin: 0 auto 20px">
<script>
googletag.cmd.push(function() { googletag.display('div-gpt-ad-1549639897910-0'); });
</script>
</div></div>
<p>This has always been a messy and potentially hazardous job, particularly when installing pipework at height. Both materials take time to apply, and this must be carried out externally.</p>
<p>Although sealing around pipes would seem like bread and butter for most, when it comes to sealing pipes or installing flues on upper floors, it can get tricky. Traditionally, the job has required mortar or silicone adhesives but they have their drawbacks: they are weather-dependent, time-consuming, and their durability may be questionable.</p>
<p><a href="https://phpdonline.co.uk/wp-content/uploads/2024/02/Site-inspection-easy.jpg"><img decoding="async" class="alignnone  wp-image-26100" src="https://phpdonline.co.uk/wp-content/uploads/2024/02/Site-inspection-easy-712x1024.jpg" alt="" width="360" height="518" srcset="https://phpdonline.co.uk/wp-content/uploads/2024/02/Site-inspection-easy-712x1024.jpg 712w, https://phpdonline.co.uk/wp-content/uploads/2024/02/Site-inspection-easy-209x300.jpg 209w, https://phpdonline.co.uk/wp-content/uploads/2024/02/Site-inspection-easy-768x1104.jpg 768w, https://phpdonline.co.uk/wp-content/uploads/2024/02/Site-inspection-easy-1068x1536.jpg 1068w, https://phpdonline.co.uk/wp-content/uploads/2024/02/Site-inspection-easy-1424x2048.jpg 1424w, https://phpdonline.co.uk/wp-content/uploads/2024/02/Site-inspection-easy.jpg 1752w" sizes="(max-width: 360px) 100vw, 360px" /></a></p>
<p>Applying these to pipe and brick work on upper storeys requires ladders, scaffolding or a cherry picker, which is costly and potentially dangerous.</p>
<p>Despite a wealth of health and safety initiatives in recent years, falls from height remain a major cause of severe injuries and fatalities at work. The Health and Safety Executive (HSE) reported 135 fatalities in work-related accidents in 2022/23; falls from height was the leading cause, killing 40 people. Thus the HSE advises to avoid work at height where it is reasonably practicable to do so.</p>
<p>&nbsp;</p>
<p><span style="color: #0084dc;"><strong>But how can you seal pipework up high without getting up there to do it?</strong></span></p><div id="phpdo-476524926" class="phpdo-content_2 phpdo-entity-placement"><!-- /111384791/phpd-inline-mpu-2 -->
<div id='div-gpt-ad-1549639916894-0' style="border: 0pt none;width: 300px; margin: 0 auto 20px">
<script>
googletag.cmd.push(function() { googletag.display('div-gpt-ad-1549639916894-0'); });
</script>
</div></div>
<p>As a result, the building industry is increasingly looking towards new, safer methods and products. These proprietary solutions, such as pipe collars or grommets, aim to streamline compliance with Part L, minimizing the need for high-risk tasks while ensuring professional, lasting results. They can be fitted on the outside of a building from within, through the cored drilled hole, as they are flexible enough to be pushed out of the brickwork and rigid enough to pop back into place, providing an air and watertight seal flush against the wall.</p>
<p><a href="https://phpdonline.co.uk/wp-content/uploads/2024/02/Energy-efficiency-on-fabric-of-building.jpg"><img decoding="async" class="alignnone size-large wp-image-26101" src="https://phpdonline.co.uk/wp-content/uploads/2024/02/Energy-efficiency-on-fabric-of-building-1024x683.jpg" alt="" width="1000" height="667" srcset="https://phpdonline.co.uk/wp-content/uploads/2024/02/Energy-efficiency-on-fabric-of-building-1024x683.jpg 1024w, https://phpdonline.co.uk/wp-content/uploads/2024/02/Energy-efficiency-on-fabric-of-building-300x200.jpg 300w, https://phpdonline.co.uk/wp-content/uploads/2024/02/Energy-efficiency-on-fabric-of-building-768x512.jpg 768w, https://phpdonline.co.uk/wp-content/uploads/2024/02/Energy-efficiency-on-fabric-of-building-765x510.jpg 765w, https://phpdonline.co.uk/wp-content/uploads/2024/02/Energy-efficiency-on-fabric-of-building.jpg 1200w" sizes="(max-width: 1000px) 100vw, 1000px" /></a>They give the outer facade of the building a clean finish, prevent the ingress of insects and pests and also ensure the house is draught proof and meets the requirements of energy efficiency stipulated under Part L.</p>
<p>No other materials have to be used to seal the hole around the pipe or flue other than the seals. There is no need for costly scaffolding or ladders and they remove the health and safety risks in working at height.</p>